Cable operated dampers are adjusted via rotary cable actuation using either a nut driver or screwdriver.
Cable operated volume dampers.
Bowden remote cable system.
Dampers above a hard ceiling or in any inaccessible location can be controlled with the ebdp electronic balancing damper positioner which opens and closes the damper and provides a visual indication of the damper position with an lcd meter.
Satisfactory the cable position is locked with a set screw and the cable is.
The rotary actuation cable is routed from the damper to the room side access point and the cable tip is positioned for easy access.
Pushed into the neck of the air device hidden from view.
Round cable control inside air stream.
Rectangular shaft driven cable control damper 5020cc.
Volume control blades move simultaneously in opposite directions to provide superior metering and control with minimal disturbance of the air pattern.
The damper line consists of cable operated and battery powered dampers.
Round cable control outside air stream 5020cc2.
The agr 35 aa s is a remote cable operated damper for duct mount applications remote snap in cable assembly including mounting hardware is shipped loose for field mounting gang operated opposed blades meter air volume with minimal air disturbance.
The gear driven cable operated damper is mounted upstream of the air device with the control cable inside or outside of the airstream.
Codr xcodr round cable operated damper codr internal cable mount xcodr external cable mount installation of a cable operated balancing damper allows the balancing con.
Installation of a gear driven cable operated damper allows the balancing contractor a convenient way to adjust air volume from a more accessible location without having to access the ceiling.
Bowden cable system controllers.
Once the air volume is.
Cable operated dampers allow the balancing contractor a convenient way to adjust air volume from a more accessible location.
The roto twist series of radial round and rectangular cable operated dampers are designed to allow damper adjustment through the face or the diffuser or grille or from a small access point in the ceiling or wall.
Constant air with ceiling radiation damper for supply.
Manually adjustable from regulator face.
Both designs offer models that allow damper adjustment through the face of the air outlet or from a remote access point in a wall ceiling or closet.
Bowden remote cable system.
The adjustment cable is routed to an appropriate area.
Round remote cable operated in bellmouth take off.
For optimized sound performance it is recommended to match an upstream duct branch damper for large volume control with a damper at the diffuser for fine tuning.